Model Parameter |
Lab usage |
Production usage |
|||||
NTI-THL-54W |
NTI-THL-243W |
NTI-THL-300W |
NTI-THL-400W |
NTI-THL-720W |
NTI-THL-720+NW |
||
Working size |
mm |
300×300×600 |
450×450×1200 |
500×500×1200 |
500×500×1600 |
600×600×2000 |
(600-800)×(600-800)×(2000-4000) |
Control process |
|
Thyristor control |
|||||
Heating type |
/ |
Resistance heating |
|||||
HT zone capacity |
L |
54 |
243 |
300 |
400 |
720 |
720+N |
Loading weight |
g |
HT zone capacity × density (g/cm³)×1000 Remark:1L=1000cm³ |
|||||
Ultimate vacuum |
Pa |
20 |
|||||
IF power |
Kw |
50 |
105 |
120 |
135 |
189 |
189-500 |
Heating zone |
Zone |
1 |
3 |
3 |
3 |
3 |
3-6 |
Max. working temperature |
℃ |
1600 |
1600 |
1600 |
1600 |
1600 |
1600 |
Usual working temperature |
℃ |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
Temperature unifomity |
℃ |
±5 |
±5 |
±5 |
±5 |
±5 |
±10 |
Working environment |
/ |
Vacuum or Ar, N2 atmosphere protection( micro positive pressure) |
|
model |
NTI-THL-400W |
max.temperature |
1600℃ |
Working tem. |
1500℃ |
Input voltage |
380V±10%,50Hz/60Hz |
Rated power |
135 KW |
Heating area |
3 regions |
HT area size |
540 mm × 540 mm × 1600 mm |
Effective heating |
Constant tem.area: 500 mm × 500 mm × 1600 mm |
Tem.measurement |
Tungsten rhenium thermocouple(0℃--1700℃) |
tem.controlling |
SHIMADNE automatic control and high precision adjustable manual control.(accuracy:0.3) |
Exhaust way |
Smart or manual for choice. |
Accuracy |
±0.25% tips:up to infrared probe accuracy grade |
tem.uniformity |
≤±5℃。(after 30min of heating ) |
Inner atmospher |
Vacuum or Ar、N2 atmospher(micro-positive pressure) |
Alarm system |
PLC smart pre-alarm、alarm and power supply protection |
Filtration |
4 grades purifing system |
Cooling |
Closed inner circulating water cooling/ FBP-2A |
purifing |
Argon gas purifier /GYA-4C |
IPC |
MCGS (TPC1061Ti),(DELTA)PLC |
Vacuum system |
Side valve type vacuum pumpH-150( 1set)、vacuum valve、pipeline and vacuum gauge Vacuum degree:20pa
|
Total weight |
About 5 tons |