Model no |
NTI-SML-4L |
NTI-SML-9L |
Ultimate working temperature |
3200℃ |
3000℃ |
Usual working temperature |
3000℃ |
2800℃ |
Input power |
380V±10%,50Hz/60Hz, 3 phase |
380V±10%,50Hz/60Hz, 3 phase |
Rated power |
60 KW |
75KW |
Intermediate frequency |
2500Hz |
2500Hz |
Working size |
Φ 150 × L 250 mm |
Φ 200 × L 300 mm |
Workable capacity |
4L |
9L |
Control type |
IGBT control |
IGBT control |
Temperature measure |
American Raytek infrared tem.measure(1000℃--3200℃)±0.75% full range. American Raytek temperature measure 250-1400℃ |
American Raytek infrared tem.measure(1000℃--3200℃)±0.75% full range. American Raytek temperature measure 250-1400℃ |
Temperature control |
Japanese Shimaden FP93 |
Japanese Shimaden FP93 |
Exhaust type |
Auto. exhaust |
Auto. exhaust |
Temperature uniformity |
≤±10℃。Remark::after keeping temperature for 30min. |
≤±10℃。Remark::after keeping for 30min. |
Inside working atmosphere |
Vacuum or Argon(micro positive pressure) |
Vacuum or Argon(micro positive pressure) |
Protection type |
PLC aptitude early warming, warming and power safety protection. |
PLC aptitude early warming, warming and power safety protection. |
Cooling type |
Closed inner circulating water cooling system: chiller NTI-LSJ-120 |
Closed inner circulating water cooling system: chiller NTI-LSJ-120 |
Gas purifier |
Model: NTI-QTJH-4 |
Model: NTI-QTJH-4 |
IPC |
Nuotian technology touch screen TPC1071 and Simens PLC SMART-200 |
Nuotian technology touch screen TPC1071and Simens PLC SMART-200 |
Vacuum system |
Rotary-vane vacuum pump 2X-4, vacuum valve, pipe and vacuum instrument. |
Rotary-vane vacuum pump 2XZ-4, vacuum valve, pipe and vacuum instrument. |
Furnace outer size |
L2000×W1000×H1600mm |
L2200×W1200×H1800mm |
Chiller outer size |
L1500xW720xH1500mm |
L1500xW720xH1500mm |
Equipment weight |
2T |
2.5T |